Cartridge and Servo Cartridge Valves
2-Way Servo Cartridge Valves X700 Series
Moog’s X700 Series Servo Cartridge Valves are throttle valves for use in 2-way applications. These valves are suitable for electrohydraulic control systems, including those with high dynamic response requirements. The seated poppet design ensures that the connection between the A and B ports is sealed off leakage free when closed. This product family is equipped with integrated electronics and closed-loop position control for the main stage cartridge poppet. For maximum flexibility, customers can choose to have an analog or fieldbus interface, or both combined in the same valve.
The new innovative design of the main stage cartridge valve results in very high flow performance. Due its robustness, the Moog X700 Series provides reliable control for die casting machines, metal presses and heavy industrial equipment, as well as other applications.
This product series is easily integrated and configurable to meet your exact application and performance requirements. For applications with safety requirements fail-safe options are available that ensure a defined, safe main stage position to avoid uncontrolled machine movements.
Specifications | X702 | X703 | X704 |
---|---|---|---|
Size according to ISO 7368 | Size 32 | Size 40 | Size 50 |
Mounting pattern |
ISO 7368- |
ISO 7368- 10-7-1-16 |
ISO 7368- 11-9-1-16 |
Hydraulic Data | |||
Main stage: maximum operating pressure of main stage ports A, B | 420 bar |
420 bar |
420 bar |
Rated flow at ΔpN 5 bar (75 psi) 1) flow direction A-B |
1,850 l/min |
2,600 l/min |
3,600 l/min (951 gpm) |
Rated flow at ΔpN 5 bar (75 psi) 1) flow direction B-A |
|
|
2,700 l/min (713 gpm) |
Recommended maximum flow | 2,700 l/min |
4,100 l/min |
6,300 l/min |
Step response time according to ISO 10770-1 (px = 210 bar)2) |
|
|
|
Electrical Data | |||
Supply voltage | 24 VDC min. 18 VDC max. 36 VDC |
24 VDC min. 18 VDC max. 36 VDC |
24 VDC min. 18 VDC max. 36 VDC |
Command signal options | 0 - 10 V; 4 - 20 mA; |
0 - 10 V; 4 - 20 mA; fieldbus |
0 - 10 V; 4 - 20 mA; fieldbus |
1) The maximum flow velocity in the A-port of the cavity should not exceed 30 m/s. Values valid for the use with recommended cavity diameters of A- and B-port (see catalog sections “Cavity Dimensions“).
2) Step response time for 0 to 90 % at 0 to 100 % step.