2-Way Servo Cartridge Valves X700 Series

Moog’s X700 Series Servo Cartridge Valves are throttle valves for use in 2-way applications. These valves are suitable for electrohydraulic control systems, including those with high dynamic response requirements. The seated poppet design ensures that the connection between the A and B ports is sealed off leakage free when closed. This product family is equipped with integrated electronics and closed-loop position control for the main stage cartridge poppet. For maximum flexibility, customers can choose to have an analog or fieldbus interface, or both combined in the same valve.

The new innovative design of the main stage cartridge valve results in very high flow performance. Due its robustness, the Moog X700 Series provides reliable control for die casting machines, metal presses and heavy industrial equipment, as well as other applications.

This product series is easily integrated and configurable to meet your exact application and performance requirements. For applications with safety requirements fail-safe options are available that ensure a defined, safe main stage position to avoid uncontrolled machine movements.

Specifications X702 X703 X704
Size according to ISO 7368 Size 32 Size 40 Size 50

Mounting pattern

ISO 7368-
09-5-1-16

ISO 7368-
10-7-1-16
ISO 7368-
11-9-1-16
Hydraulic Data      
Main stage: maximum operating pressure of main stage ports A, B

420 bar
(6,000 psi)

420 bar
(6,000 psi)

420 bar
(6,000 psi)

Rated flow at ΔpN 5 bar (75 psi) 1)
flow direction A-B

1,850 l/min
(489 gpm)

2,600 l/min
(687 gpm)

3,600 l/min
(951 gpm)
Rated flow at Δp5 bar (75 psi) 1)
flow direction B-A


1,300 l/min
(343 gpm)


1,900 l/min
(502 gpm)

2,700 l/min
(713 gpm)
Recommended maximum flow

2,700 l/min
(713 gpm)

4,100 l/min
(1,083 gpm)

6,300 l/min
(1,664 gpm)

Step response time according to ISO 10770-1 (px = 210 bar)2)


11 ms


13 ms


16 ms

Electrical Data      
Supply voltage 24 VDC
min. 18 VDC
max. 36 VDC
24 VDC
min. 18 VDC
max. 36 VDC
24 VDC
min. 18 VDC
max. 36 VDC
Command signal options

0 - 10 V; 4 - 20 mA;
fieldbus

0 - 10 V; 4 - 20 mA;
fieldbus
0 - 10 V; 4 - 20 mA;
fieldbus

1) The maximum flow velocity in the A-port of the cavity should not exceed 30 m/s. Values valid for the use with recommended cavity diameters of A- and B-port (see catalog sections “Cavity Dimensions“).

2) Step response time for 0 to 90 % at 0 to 100 % step.